| Life at hight temperature |
per IEC 68-2-2
|
1000 hours
95°C case
|
| Humidity |
per IEC 68-2-3
Test Ca
|
Damp heat : 93 % H.R 56 days
Temperature : 40°C
|
| Temperature cycling |
per IEC 68-2-14 Test N
|
Number of cycles : 200
Temperature change : -40°C/+71°C
Transfer time : 40 min.
Steady state time : 20 min.
|
| Vibration |
per IEC 68-2-6
Test Eb
|
10 cycles in each axis
Frequency : 10 to 60Hz/60Hz to 2kHz
Amplitude/acceleration : 0,7 mm/10 g |
| Shock |
per IEC 68-2-27 Test Ea
|
3 cycles in each axis
Peak acceleration : 100 g
Duration : 6 ms |
| Bumps |
per IEC 68-2-29 Test Eb
|
2.000 bumps in each directions
Duration : 6 ms
Peak acceleration : 25 g |
| Electrical discharge susceptibility |
per EN55082-2
with EN61000-4-2
(IEC 801-2) |
Air discharge level 4 kV : sanction A Contact discharge level 2 kV : sanction A
Air discharge level 8 kV : sanction B
Contact discharge level 4 kV : sanction B |
| Electrical field susceptibility |
per EN55082-2
with EN61000-4-3
(IEC 801-3) |
Antenna at 1 m distance
Value applied : 10V/m
Waveform : AM modulated 80 % 1 kHz test : 26 MHz to 1 Ghz |
| Electrical fast transient usceptibility |
per EN55082-2
with EN61000-4-4
(IEC 801-4) |
Level 1 : 0,5 kV sanction A : module stand alone
Level 3 : 2 kV sanction B : module stand alone
Level 4 : 4 kV sanction A : with external filter
Waveform : 5/50 µs impedance 50 Ohm |
Surges transient susceptibility
(see technical datasheet for complete details) |
per EN55082-2
with EN61000-4-5
(IEC 801-5)
per EN50155 |
Level 4 : 4 kV sanction A : with external filter
Waveform : 1.2/50 µs impedance 12 Ohm
Level 1,8 : 4 kV sanction A : with external filter
Waveform : 5/50 µs impedance 5 Ohm
|